Exploded diagrams, Schematics and other documents

Click on an image to enlarge the exploded view

AR72B Parts List

Rail-mounted terminal WIELAND type 9700A/8 S35 1.0-10mm² top-hat

Rail-mounted terminal WIELAND type 9700A/8 S35 1.0-10mm² top-hat

Ref: Pg:1 Item:

Rail-mounted terminal WIELAND type 9700A/8 S35 1.0-10mm² top-hat

Fan wheel blades 42 D1 ø 355mm D2 ø 14mm D3 ø 14mm H1 114mm H2 2

Fan wheel blades 42 D1 ø 355mm D2 ø 14mm D3 ø 14mm H1 114mm H2 2

Ref: Pg:1 Item:

Fan wheel blades 42 D1 ø 355mm D2 ø 14mm D3 ø 14mm H1 114mm H2 2

Push button latch L 180mm mounting distance 121mm non lockable 6

Push button latch L 180mm mounting distance 121mm non lockable 6

Ref: Pg:1 Item:

Push button latch L 180mm mounting distance 121mm non lockable 6

Indicator light ø 16mm yellow connection F6.3 temp.-resist. 120°

Indicator light ø 16mm yellow connection F6.3 temp.-resist. 120°

Ref: Pg:1 Item:

Indicator light ø 16mm yellow connection F6.3 temp.-resist. 120°

Safety thermostat switch-off temp. 340°C 1-pole 1NC 16A probe ø

Safety thermostat switch-off temp. 340°C 1-pole 1NC 16A probe ø

Ref: Pg:1 Item:

Safety thermostat switch-off temp. 340°C 1-pole 1NC 16A probe ø

Timer M2 2-pole operation time 90min impulse mechanical 2NO at 2

Timer M2 2-pole operation time 90min impulse mechanical 2NO at 2

Ref: Pg:1 Item:

Timer M2 2-pole operation time 90min impulse mechanical 2NO at 2

Rail-mounted terminal WIELAND type 9700A/6 SL2 S35 0.5-4mm² top-

Rail-mounted terminal WIELAND type 9700A/6 SL2 S35 0.5-4mm² top-

Ref: Pg:1 Item:

Rail-mounted terminal WIELAND type 9700A/6 SL2 S35 0.5-4mm² top-

Rail-mounted terminal WIELAND type WK10/SIU 5X20 /V0 suitable fu

Rail-mounted terminal WIELAND type WK10/SIU 5X20 /V0 suitable fu

Ref: Pg:1 Item:

Rail-mounted terminal WIELAND type WK10/SIU 5X20 /V0 suitable fu

Power contactor resistive load 40A 230VAC (AC3/400V) 25A/11kW ma

Power contactor resistive load 40A 230VAC (AC3/400V) 25A/11kW ma

Ref: Pg:1 Item:

Power contactor resistive load 40A 230VAC (AC3/400V) 25A/11kW ma

Fine fuse size ø5x20mm 2A slow-acting rated 250V Qty 10 pcs

Fine fuse size ø5x20mm 2A slow-acting rated 250V Qty 10 pcs

Ref: Pg:1 Item:

Fine fuse size ø5x20mm 2A slow-acting rated 250V Qty 10 pcs

Power contactor resistive load 40A 230VAC (AC3/400V) 25A/11kW ma

Power contactor resistive load 40A 230VAC (AC3/400V) 25A/11kW ma

Ref: Pg:1 Item:

Power contactor resistive load 40A 230VAC (AC3/400V) 25A/11kW ma

Motor protection circuit breaker type  setting range 0.63-1A (AC

Motor protection circuit breaker type setting range 0.63-1A (AC

Ref: Pg:1 Item:

Motor protection circuit breaker type setting range 0.63-1A (AC

Fan motor 0,32kW L1 200mm L2 80mm D1 ø 14mm A at 50Hz 200-240/34

Fan motor 0,32kW L1 200mm L2 80mm D1 ø 14mm A at 50Hz 200-240/34

Ref: Pg:1 Item:

Fan motor 0,32kW L1 200mm L2 80mm D1 ø 14mm A at 50Hz 200-240/34

Thermostat t.max. 258°C temperature range 58-258°C 1-pole 1NC 16

Thermostat t.max. 258°C temperature range 58-258°C 1-pole 1NC 16

Ref: Pg:1 Item:

Thermostat t.max. 258°C temperature range 58-258°C 1-pole 1NC 16

Rail-mounted terminal WIELAND type 9700A/8 S35 1.0-10mm² top-hat

Rail-mounted terminal WIELAND type 9700A/8 S35 1.0-10mm² top-hat

Ref: Pg:1 Item:

Rail-mounted terminal WIELAND type 9700A/8 S35 1.0-10mm² top-hat

Heating element 18000W 380V heating circuits 3 ID ø 380mm ED ø 3

Heating element 18000W 380V heating circuits 3 ID ø 380mm ED ø 3

Ref: Pg:1 Item:

Heating element 18000W 380V heating circuits 3 ID ø 380mm ED ø 3

Front Foil Red Ar

Front Foil Red Ar

Ref: Pg:1 Item:

Front Foil Red Ar

Hanging rack Multiplus AR 72 left

Hanging rack Multiplus AR 72 left

Ref: Pg:1 Item:

Hanging rack Multiplus AR 72 left

Replaced by 6001050K

Replaced by 6001050K

Ref: Pg:1 Item:

Replaced by 6001050K

Hanging Rack LH Complete

Hanging Rack LH Complete

Ref: Pg:1 Item:

Hanging Rack LH Complete